SCN-1000-... 1000W-12V, 24V, 36V or 48V in Parallel SMPS
Features:
Single output: 1000W-12V, 24V, 36V or 48V; Input voltage: 90~132VAC/180~264VAC by switch, based on the following features,
1). High efficiency, high reliability and low cost
2). Switch-mode input voltage range choice
3). 100% full load and machine test
4). Short circuit, overload, automatic recovery, air cooling etc. protection
5). 2years warranty
Technical Specifications:
Model |
SCN-1000-12 |
SCN-1000-24 |
SCN-1000-36 |
SCN-1000-48 |
|
Rated capacity |
1000W |
1000W |
1000W |
1000W |
|
DC output voltage/current |
12V/80A |
24V/42A |
36V/28A |
48V/21A |
|
Wave and noise |
150mVp-p |
180mVp-p |
150mVp-p |
150mVp-p |
|
Inlet wire stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Efficiency |
80% |
85% |
86% |
87% |
|
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
|
Input voltage range |
90~132VAC/180~264VAC by switch, 254~370VDC, 47~63Hz |
||||
Impact current |
Cold current: 45A/230VAC |
||||
Over load protection |
105%~135% cut off the output, automatic recovery |
||||
Over voltage protection |
115%~140% shut down output, recover after re-power on |
||||
Setup, rise, hold up time |
2000ms, 50ms, 20ms/230VAC at full load |
||||
Working temperature |
-10℃~+50℃ |
||||
Safety |
Withstand Voltage |
I/P-O/P:1.5KV, I/P-FG:1.5KV, O/P-FG:0.5KV 1minute |
|||
Isolation Resistance |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ |
||||
Standard |
Safety Standard |
Design refer to UL1012 |