Products
PVT3310KS 3/3, 10KVA/8KW, 380VAC/3Phase, External 240VDC, Long-active Online HF UPS
Category:
Product Description
1. Features
1). Tower shape, True online double-conversion technology
2). Load power factor is 0.8, adaptive for the development trend of electrical
3). Equipment and the load capacity is more strong
4). Active input power factor correction(PFC), input power factor is over 0.98
5). Wide input voltage and frequency range, adaptive for extreme adverse grid environment of remote areas
6). It can be connected with generators
7). Zero transfer time effective ensures the safety and reliability of load operation
2. Applications
Widely used in Finance, Telecommunication, Government Sector, Transportation, Manufacturing, Education etc.
3. Descriptions
Professional design is specifically for small and medium enterprises, online double design, DSP digital technology, pure sine wave, excellent performance, high-grade appearance, which present the integration of advanced technology and traditional products.
3.Technical Specification
MODEL | PVT1K | PVT1KS | PVT2K | PVT2KS | PVT3K | PVT3KS | ||
Nominal Output Capacity | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | |||||
AC Input | Input voltage range | 115~300VAC+/-5 | ||||||
Input Frequency | (45~55)+/-0.5Hz | |||||||
Bypass voltage | 80VACx(1+/-5%)~285VACx(1+/-0.5Hz | |||||||
Battery Input | Battery unit voltage | 24V | 36V | 48V | 72V | 48V/72V(R) | 96V | |
Battery installation | Internal | External | Internal | External | Internal | External | ||
Backup time(Half/full) | Half load> or =10mins; Full load> or =5mins(Standard type) | |||||||
Maximum power input current | <150% of Nominal current | |||||||
Battery charge time | Long time UPS on the capacity of external battery packs | |||||||
AC Output | Output voltage | 220V+/-1%(Inverter output) | ||||||
Output frequency | 50Hz+/-5Hz(AC input Nominal); 50Hz+/-1%(AC input abnormal) | |||||||
Wave form | Sine wave THD<3%(Linear load); Sine wave THD<8%(Non-linear load) | |||||||
Output power factor(PF) | 0.8 | |||||||
Overload capacity | 130% continuous load: not less than 30s, Recovery point: 90% load | |||||||
Output current crest | 3:1 | |||||||
Transfer time | 0ms | |||||||
Communications & Monitoring Function | RS232(Optional 485), Dry contact, Intelligent Slot(Expandable SNMP, SMS, and Other monitoring mode) | |||||||
Tower | N.w.(kgs) | 8.1/8.7 | 4.5/5.2 | 14.2/15.1 | 6.2/7.1 | 22.5/24.5 | 10.5/12.5 | |
Unit size(L*W*H) mm | 285*144*222 | 400x145*225 | 420*190*320 | |||||
Marster carton size(mm) | 480*330*360 | 442*227*330 | 525*325*460 | |||||
Marster carton G.w(kgs) | 18 | 11 | 15.1 | 7.1 | 24.5 | 12.5 | ||
Qty/Marster carton(pcs) | 2 | 1 | 1 | |||||
Note: With S means long backup time UPS model
MODEL | PVT6K | PVT6KS | PVT10K | PVT10KS | PVT3110KS | PVT3115KS | PVT3120KS | ||||
Nominal Output Capacity | 6000VA/4800W | 10KVA/8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | ||||||
Rated | Nominal voltage | 220VAC | 380VAC | ||||||||
AC Input | Nominal frequency | 50Hz | 50Hz | ||||||||
Input voltage range | 120~275VAC+/-5 | 305~478VAC | |||||||||
Input frequency range | (45~55)+/-0.5Hz | (45~55)+/-0.5Hz | |||||||||
Bypass voltage | 80VACx(1+/-5%)~285VACx(1+/-5%) | 190~520VAC | |||||||||
Battery input | Battery unit voltage | Standard 192VDC(240VDC optional) | Standard 192VDC(240VDC optional) | ||||||||
Battery capacity & number | 12VDC &16pcs(20pcs optional) | External 12VDC *16pcs | |||||||||
Charge current | Charge current 4A(Long run UPS) | 4A | |||||||||
AC output | Output voltage | 220VAC+/-1%(Inverter output) | 220VAC+/-1%(Inverter output) | ||||||||
Output frequency | 46~54Hz(AC Input normal); 50Hz+/-1%(AC Input abnormal) | 46~54Hz(AC Input normal); 50Hz+/-1%(AC Input abnormal) | |||||||||
Wave form | Sine wave THD<3%(Linear load); Sine wave THD<8%(Non-linear load) | Sine wave THD<3%(Linear load); Sine wave THD<8%(Non-linear load) | |||||||||
Output power factor(PF) | 0.8 | 0.8 | |||||||||
Over load | 105~125%, Transfer to Bypass after 1min. | 105~125%, Transfer to Bypass after 1min. | |||||||||
Communication & Monitoring Function | RS232(Optional 485), Dry contact, Intelligent Slot(Expandable SNMP, SMS, and Other monitoring mode) | RS232(Optional 485), Dry contact, Intelligent Slot(Expandable SNMP, SMS, and Other monitoring mode) | |||||||||
Tower | N.w.(kgs) | 57 | 12.5 | 59 | 13.9 | 14.5 | 15.3 | 15.3 | |||
G.w.(kgs) | 64 | 13.9 | 65 | 15.3 | 15 | 16.7 | 16.7 | ||||
Unit dimension(L*W*H) mm | 502*250*610 | 444*191*320 | 425*190*320 | 444*191*323 | 465*190*323 | ||||||
Carton dimension(L*W*H) mm | 650*350*720 | 525*325*460 | 525*325*460 | 525*325*460 | 525*325*460 | ||||||
Note: With S means long backup time UPS model
Recommended Products